Skip navigation

Expert Report on Taser ECD by Gary Vilke, 2017

Download original document:
Brief thumbnail
This text is machine-read, and may contain errors. Check the original document to verify accuracy.
Case 2:15-cv-08441-JAK-AJW Document 47-2 Filed 04/03/17 Page 1 of 20 Page ID #:367

EXHIBIT 1

Case 2:15-cv-08441-JAK-AJW Document 47-2 Filed 04/03/17 Page 2 of 20 Page ID #:368

Gary M Vilke, MD., FACEP, FAAEM
11279 Breckenridge Way
San Diego, California 92131
(619) 666-8643
November 19, 2016

Christian R. Bojorquez
Deputy City Attorney
City of Los Angeles
City Hall East
200 N. Main Street, Room 800
Los Angeles, CA 90012

RE:

William Mears v. City of LA
Case: CVlS-08441 JAK (AJWx)

Introdnction

I am a board-certified emergency depaitment physician with substantial experience in
sudden cardiac arrest and sudden cardiac death, including my service as the Medical Director of the
American Heart Association Training Center at the University of California, San Diego Center for
Resuscitation Science. I am also an independent researcher on the physiologic effects of TASER
Electronic Control Devices (ECO), OC spray, restraint and weight force, as well as Excited
Delirium Syndrome (ExDS). I have served on multiple expert and consensus panels and have
published multiple peer-reviewed papers and book chapters on these topics. My qualifications are
fmther delineated at the end of my report.
I have been retained as an expe1t to review relevant materials and provide expert opinion on
this matter, including the state of the medical and scientific literature, and to consider and render
expert opinion on whether the restraining process or actions of the officers were contributory to Mr.
Michael Mears' death, and if not, what was the likely cause. After careful review, it is my opinion
to a reasonable degree of medical certainty that the use of the TASER ECO, the restraining process,

Case 2:15-cv-08441-JAK-AJW Document 47-2 Filed 04/03/17 Page 3 of 20 Page ID #:369

the OC spray and the spit mask did not cause nor were contributory to the death of Mr. Mears.
Furthermore, it is my opinion to a reasonable degree of medical certainty that Mr. Mears' cardiac
arrest resulted from Excited Delirium Syndrome from his cocaine use and facilitated from his
underlying cardiac disease and significant hyperkalemia (elevated potassium levels). These opinions
and related opinions are set forth in my report.

Materials Reviewed
I have reviewed extensive materials pertaining to the above referenced case. This includes,
but is not limited to:

Case-Specific Materials
I. Complaint for Damages Filed I 0/28/15
2. Complaint for Damages Filed 12/11/15
3. Force Investigation Division Repot1 No. F003-15
4. Autopsy Report
5. Medical Records from UCLA Medical Center
6. VA Medical Records
7. EMS Records
8. Photographs
9. Deposition of Jonathan Gan
10. Deposition of Steven Beumer
1 I. Deposition of Jose Pedroza
12. Deposition of Jessica Gist
13. Deposition of Ken Lew
14. Deposition of Andrey Wilkins

Medical and Scientific Literature
Bozeman WP, Hauda WE 2nd, Heck JJ, Graham DD Jr, Martin BP, Winslow JE. Safety and
injury profile of conducted electrical weapons used by law enforcement officers against criminal
suspects. Ann Emerg Med. 2009 Apr;53(4):480-9. Epub 2009 Jan 21.

-2-

Case 2:15-cv-08441-JAK-AJW Document 47-2 Filed 04/03/17 Page 4 of 20 Page ID #:370

Dawes D, Ho J, Miner J. The neuroendocrine effects of the TASER X26: a briefrep011.
Forensic Sci Int. 2009 Jan 10;183(1-3):14-9. Epub 2008 Nov 18.
Eastman AL, et al. Conductive electrical devices: a prospective, population-based study of the
medical safety of law enforcement use. J Trauma. 2008 Jun;64(6):1567-72.
Ho JD, Miner JR, Lakireddy DR, Bultman LL, Heegaard WG, Cardiovascular and physiologic
effects of conducted electrical weapon discharge in resting adults. Acad Emerg Med. 2006
Jun;l3(6):589-95. Epub 2006 Mar 21.
Strate J, et al. Conducted Electrical Weapon Use by Law Enforcement: An Evaluation of Safety
and Injury. J Trauma. 2009 Dec 22. [Epub ahead of print].
Vilke GM, Sloane CM, Suffecool A, Kolkhorst FW, Neuman TS, Castillo EM, Chan TC.
Physiologic effects of the TASER after exercise. Acad Emerg Med. 2009 Aug; 16(8):704-10.
Vilke GM, Sloane C, Levine S, Neuman T, Castillo E, Chan TC. Twelve-lead electrocardiogram
monitoring of subjects before and after voluntary exposure to the Taser X26. Am J Emerg Med.
2008 Jan;26(1 ): 1-4.
Vilke GM, Sloane CM, Bouton KO, Kolkhorst FW, Levine SD, Neuman TS, Castillo EM, Chan
TC. Physiological effects of a conducted electrical weapon on human subjects. Ann Emerg
Med. 2007 Nov;50(5):569-75. Epub 2007 Aug 24.
Ho J, Dawes D, Nelson RS, et al. Acidosis and catecholamine evaluation following simulated
law enforcement "use of force" encounters. Acad Emerg Med 2010 Jul; 17(7):e60-8.
Vilke GM, Bozeman WP, Chan TC. Emergency Depat1ment Evaluation after Conducted
Energy Weapon Use: Review of the Literature for the Clinician. J Emerg Med 2011;40(5):598604. Epub 2011 Jan 4.
Chan TC, Vilke GM, Neuman T, Clausen JL: Restraint position and positional asphyxia. Ann
Emerg Med I 997;30(5):578-586.
Chan TC, Vilke GM, Neuman T: Reexamination of custody restraint position and positional
asphyxia. Am J Forensic Med Pathol 1998;19(3):201-205.
Vilke GM, Chan TC, Neuman T, Clausen JL: Spirometry in normal subjects in sitting, prone,
and supine positions. Respir Care 2000;45(4):407-410.
Chan TC, Vilke GM, Clausen J, Clark R, Schmidt P, Snowden T, Neuman T: The impact of
oleoresin capsicum spray on respiratory function in human subjects in the sitting and prone
maximal restraint positions, final report. NCJ 182433. Washington, DC: United States
Department of Justice, National Institute of Justice, 2000, 68 pages.

-3-

Case 2:15-cv-08441-JAK-AJW Document 47-2 Filed 04/03/17 Page 5 of 20 Page ID #:371

Chan TC, Vilke GM, Clausen J, Clark RF, Schmidt P, Snowden T, Neuman T: The effect of
oleoresin capsicum "pepper" spray inhalation on respiratory function. J Forensic Sci 2002;
47(2):299-304.
Chan TC, Neuman T, Clausen J, Eisele J, Vilke GM: Weight force during prone restraint and
respiratory function. Am J Forensic Med Pathol 2004;25(3): 185-189.
Michalewicz BA, Chan TC, Vilke GM, Levy SS, Neuman TS, Kolkhorst FW. Ventilatory and
metabolic demands during aggressive physical restraint in healthy adults. J Forensic Sci
2007;52(1): 171-175.
Reay DT, Howard JD, Fligner CL, Ward RJ. Effects of positional restraint on oxygen saturation
and heart rate following exercise. Am J Forensic Med Pathol. 1988 Mar;9(1):16-8.
Schmidt P, Snowden T. The effects of positional restraint on heart rate and oxygen saturation. J
Emerg Med 1999; 17:777-782.
Vilke GM, Sloane C, Castillo EM, Kolkhorst FW, Neuman TS, Chan TC. Evaluation of the
Ventilatory Effects ofa Restraint Chair on Human Subjects .. J Emerg Med. 2011;40(6):714-8.
Epub 2010 Jan 13.
Savaser DJ, Campbell C, Castillo EM, Vilke GM, Sloane C, Neuman T, Hansen AV, Shah S,
Chan TC. The effect of the prone maximal restrained position with and without weight force on
cardiac output and other hemodynamic measures. J Forens Leg Med. 2013 Nov;20(8):991-5.
Epub 2013 Aug 30.
Sloane C, Chan TC, Kolkhorst F, Neuman T, Castillo EM, Vilke GM. Evaluation of the
Ventilatory Effects of the Prone Maximum Restraint Position (PMR) on Obese Human Subjects.
Forens Sci Int 2014;237:86-9. Epub 2014;46(6):865-72. Epub 2014 Feb 14.
Cary NRB, et al: The effect of simulated restraint in the prone position on cardiorespiratory
function following exercise in humans. J Physiol 1998;525 :30.
Ho JD, Dawes DM, Moore JC, Caroon LV, Miner JR: Effect of position and weight force on
inferior vena cava diameter--implications for arrest-related death. Forensic Sci Int. 2011 Oct
10;212(1-3):256-9.
Vilke GM, Payne-James J, Karsch SB. Excited Delirium Syndrome (ExDS): Redefining an
Old Diagnosis. JForens Legal Med. 2012;19:7-l l.
Vilke, GM, Bozeman WP, Dawes DM, DeMers, G, Wilson MP. Excited delirium syndrome
(ExDS): Treatment options and considerations. J Forens Legal Med. [Epub 2012 Jan 24]
Vilke GM, DeBatd ML, Chan TC, Ho JD, Dawes DM, Hall C, Curtis MD, Costello MW, Mash
DC, Coffman SR, McMullen MJ, Metzger JC, Roberts JR, Sztajnkrcer MD, Henderson SO,
Adler J, Czarnecki F, Heck J, Bozeman WP. Excited Delirium Syndrome (ExDS): Defining
Based on a Review of the Literature. J Emerg Med. [Epub 2011 Mar 24]

-4-

Case 2:15-cv-08441-JAK-AJW Document 47-2 Filed 04/03/17 Page 6 of 20 Page ID #:372

Wilson MP, Vilke GM. The patient with excited delirium in the emergency department. In Zun
LS, Chepenik LG, Mallory MNS editors. Behavioral Emergencies: A handbook for emergency
physicians. Cambridge: Cambridge University Press; 2013.
Hughes, E.L., Special Report, Special Panel Review of Excited Delirium, Less-Lethal Devices
Technology Working Group, NIJ Weapons and Protective Systems Technologies Center, Penn
State.
White Paper Report on Excited Delirium Syndrome. ACEP Excited Delirium Task Force,
http://ccpicd.com/Documents/Excited%20Delirium%20Task%20Force.pdf; September 10,
2009.
Jauchem J. Pathophysiologic changes due to TASER devices versus excited delirium: Potential
relevance to deaths-in-custody? J Forensic Leg Med. May 2011 ;18(4): 145-153.
Bell, L. On a form of disease resembling some advanced stages of mania and fever, but so
contradistinguished from any ordinary observed or described combination of symptoms as to
render it probable that it may be overlooked and hitherto unrecorded malady. American Journal
oflnsanity. 1849; 6:97-127.

Overview of Opinions
(all opinions within this report are to a reasonable degree of medical or
scientific probability)
An overview of my opinions is as follows with more description of each below:

1. The use of the TASER ECD did not cause or contribute to the cardiac arrest and death
of Mr. Mears.

2. The restraining process did not cause the sudden cardiac arrest and death in Mr.
Mears.
3. The OC spray used on Mr. Mears did not cause or contribute to his cardiac arrest and
death.
4. The spit mask used on Mr. Mears did not cause or contribute to his cardiac arrest and
death.
5. Mr. Mears had an enlarged heart that placed him at significant risk of going into
sudden cardiac arrest and dying.
6. Mr. Mears was suffering signs and symptoms consistent with excited delirium
syndrome due to his cocaine use, which in and of itself can cause sudden cardiac arrest.

-5-

Case 2:15-cv-08441-JAK-AJW Document 47-2 Filed 04/03/17 Page 7 of 20 Page ID #:373

7. The significant hyperkalemia (elevated potassium levels) that Mr. Mears had
contributed to his cardiac arrest and sudden death.

Analysis
After reviewing the above listed materials, it appears that on December 24, 2014, Mr.
Michael Mears started acting paranoid and delusional at the apartment in which he shared with
Ingrid Lehman. Ingrid was concerned and called the apartment security to come and assist with Mr.
Mears. Mr. Mears was 39 years old, 6' l" tall and weighed approximately 305 pounds at the time.
Shortly after seeing Mr. Mears' behavior, the security guard called 911 to get EMS medical
assistance. Paramedics were dispatched and arrived and realized that they needed additional back up
and so an engine company was called for assistance. Mr. Mears was noted to be rolling around in
the hallway on broken glass and he was covered in blood. Due to his violent activity, police back up
was called to assist getting him into a safe and secure condition so that medical treatment could be
initiated.
Two Los Angeles police department officers aiTived, Officers Beumer and Pedroza. After
assessing the situation, they requested additional back up as well as a TASER ECD and a beanbag
shotgun be brought to the scene. Once additional officers arrived, the officers went hands-on with
Mr. Mears, utilizing the TASER ECD multiple times to gain control over him and to get him
restrained. Ultimately he was restrained and treatment was initiated by the paramedics. He was then
transported to UCLA medical center. He was at UCLA medical center for over 30 minutes when
his medical condition changed and he went into a PEA cardiac arrest. He was treated with
medications and regained his pulse for a period of time but then later again went into cardiac arrest.
He was found to be in renal failure with a dangerously elevated potassium level. Mr. Mears was
resuscitated once again, regaining a heartbeat and blood pressure but not consciousness.

-6-

Case 2:15-cv-08441-JAK-AJW Document 47-2 Filed 04/03/17 Page 8 of 20 Page ID #:374

Ultimately, he never did regain consciousness and eventually died on December 26, 2014 in the
hospital.
Given this history, there are a number of issues that need to be addressed in more detail
below. All opinions given are to a reasonable, or higher, degree of medical probability based on the
information currently available.

Detailed discussion and basis of opinions

1. The use of the TASER ECD did not cause or contribute to the cardiac arrest and death of
Mr.Mears.
There is a great deal of unwarranted concern of electrocution based on lay misunderstanding
of the reported 50,000 volts (V) peak open arcing voltage used by TASER handheld ECDs. TASER
handheld ECDs deliver only a fraction of the 50,000 V to the body. In the case of the TASER X26
ECO, the mean delivered pulse voltage is 580 V.
However, it is not the voltage, but the delivered electrical charge, that actually creates a risk
for cardiac effects. For example, the static electricity from walking across a carpet can generate
30,000 to 100,000 V. However, the average actual delivered electrical current of the TASER X26
ECD is only about 1.9 milliamperes (mA) (or, 0.0019 amperes (A)) and the peak current is only
about 3 A. By way of comparison, a Christmas tree light string will have on average current of 0.4
A or 400 mA, which is about 200 times the average delivered current of the TASER X26 ECD.
The amount of delivered electrical energy available to be transferred to a person is limited as
the TASER X26 ECD is only powered by a battery of two 3 V cells (Duracell® CR123s),
commonly used in some small digital cameras (such as the Nikon F6), not an electrical outlet or
power generator. It is the TASER ECD's rapid cycling that can cause the subjects' muscles to

-7-

Case 2:15-cv-08441-JAK-AJW Document 47-2 Filed 04/03/17 Page 9 of 20 Page ID #:375
I

contract at about 19 times a second that can offer the effective incapacitation of the subject in probe
mode, or painful compliance in drive-stun mode, while still offering a significant safety margin
from electrical injury. Once the energy from an ECD is turned off, the subject is back to his
physical baseline.
In order for an ECD to deliver a charge to the person the electrical circuit must be completed
and maintained. If wires are broken, loose or there is a loss of connection, there will be TASER
ECD download recordings of the discharge, despite there not being any actual delivered charge
being applied to the subject. Thus, just because the TASER ECD download recorded a trigger pull,
does not mean that the TASER ECD was indeed in contact with the subject and delivering the
electrical stimulus.
There are no peer-reviewed published scientific or medical literature studies that
conclusively demonstrate that TASER ECDs cause cardiac dysrhythmias or cardiac arrest in
humans. More than 1.5 million volunteer subjects have undergone TASER ECD activations, and
none have ever been reported to develop sudden cardiac an-est or die. Just because a TASER ECD
was being used in proximity to his death, does not imply causation.
The TASER ECD data download from Officer Gan's device showed six trigger pulls over a
time period of just under four minutes. The total time from the trigger pulls was 53 seconds of
activation time (5, 32, 3, 5, 5, and 3 seconds each). As noted previously, in order for an ECD to
deliver a charge to the person the electrical circuit must be completed and maintained. Thus, as a
point of clarification, just because the TASER ECD download recorded 53 seconds of activation
time from the TASER ECD, does not mean that the TASER ECD was indeed in contact with the
subject and delivering the electrical stimulus for that amount of time. Often with moving,
squirming, rolling and kicking, the contact of the device to the skin is disrupted.

If the TASER ECD had "electrocuted" Mr. Mears, his heart would have gone into a
ventricular fibrillation (VF) at the time the electricity was being delivered and he would have

-8-

Case 2:15-cv-08441-JAK-AJW Document 47-2 Filed 04/03/17 Page 10 of 20 Page ID
#:376

immediately lost consciousness at the time that the TA SER ECO was firing or within 1-2 seconds
after stopping. Subjects in VF cannot fight or struggle, let alone remain conscious as the blood
flow to the brain ceases immediately. The fact that Mr. Mears was alive for an hour after the last
TASER ECD activation confirms that the TASER ECO did not cause his heart to go into cardiac
arrest. There are no delayed electrocutions. The cardiac arrest happens at the time the electricity is
applied, not later. This conclusion is also suppmted in that Mr. Mears was in a normal, albeit fast,
cardiac rhythm when he was subsequently placed onto a cardiac monitor.
In order for one to possibly conclude that a TASER ECO could even be considered to cause
cardiac arrest, all of the following facts would need to be present:
1) The device probes would need to be penetrating deep into the chest wall for the tips to be
close to the heart (a close datt to heart ratio);
2) The subject would need to have a thin chest wall;
3) The subject would need to be standing at the time of the TASER ECO activation and
leaning forward so that the heart is closer to the anterior chest wall;
4) The subject would need to lose consciousness immediately during the TASER ECO
activation or with 1-2 seconds after; and
5) The first cardiac rhythm would need to be ventricular fibrillation.
All of these would be needed to even consider the TA SER ECO as the cause of death, but in
this case with Mr. Mears, these facts are simply not present. In summary, all of the published
scientific data as well as the objective evidence available in this case confirms that the use of the
TA SER ECO was non-contributory to the cardiac arrest and death of Mr. Mears.

2. The restraining process did not cause the sudden cardiac arrest and death in Mr. Mears.

-9-

Case 2:15-cv-08441-JAK-AJW Document 47-2 Filed 04/03/17 Page 11 of 20 Page ID
#:377

During the period that Mr. Mears was being handcuffed, he was restrained in a prone
position with a ce1iain amount of weight placed on him initially to gain control over him. After Mr.
Mears was restrained he was evaluated and treated by the EMS providers and transpotied to the
hospital. He was alive for about an hour after the restraining process. He was not reported to
complain of shortness of breath or difficulty breathing after being restrained and being tended to by
the paramedics. He was reported to have clear lungs, unlabored breathing and a strong pulse of 190
beats/minute.
As Mr. Mears was alive for an hour after being restrained, this could not be an asphyxia!
death. Asphyxiation does not occur in a delayed fashion. If the weight force by the officers
impacted Mr. Mears' ability to ventilate to the point of causing a cardiac arrest and sudden death by
asphyxiation, the ventilations would have had to be restricted long enough to where blood oxygen
levels would drop because there was not enough oxygen getting into Mr. Mears' lungs. When this
occurs, the low blood oxygen levels will cause the heart to become irritable and eventually slow and
then stop and the subject goes into cardiac arrest. This would be evident at the time the weight was
removed if the position and weight force was responsible for asphyxiation. This does not happen in
a delayed fashion as once weight is removed and ventilations restored, the subject will quickly
return to normal oxygen levels in the blood. In this case, Mr. Mears was breathing and had a pulse
well after he was restrained.
Given that Mr. Mears was alive before, during, and after the restraining, and that the cardiac
arrest occul'l'ed an hour later at the hospital, the effort to restrain him and any weight force applied
during the restraining process did not cause or contribute to Mr. Mears' cardiac arrest and death.
There is no evidence that position, restraint or body weight caused or contributed to Mr. Mears'
death.

3.
and death.

The OC lpray used on Mr. Mears did not cause or contribute to his cardiac arrest

- IO -

Case 2:15-cv-08441-JAK-AJW Document 47-2 Filed 04/03/17 Page 12 of 20 Page ID
#:378

Although Mr. Mears was exposed to OC spray, there are no findings that this exposure was
a contributing factor in his death. Shortness of breath associated with allergic reactions or reactive
airway exacerbations have been reported with OC spray, similar to an allergic reaction a person
would have to a cat or serious pollen allergy. When these types of reactions occur with OC spray,
they occur almost immediately after exposure and have physical findings of wheezing and
bronchospasm.
In this case, Mr. Mears was noted to be breathing without difficulty well after the OC spray
was used with no evidence of wheezing or issues with being able to ventilate, which demonstrates
no evidence of an allergic reaction. Acute anaphylactic reactions typically occur rapidly at the time
of the exposure and are obvious. This was not the case with Mr. Mears. The OC spray exposure
was non-contributory to Mr. Mears' death.

4. The spit mask used on Mr. Mears did not cause or contribute lo his cardiac arrest and
death.
Mr. Mears had a spit mask placed on him for personal protection of the officers and medical
staff working with him. This is reasonable and prudent. The mask has a mesh material that covers
the head. This mesh material allows for air to pass through and does not impede one's ability to
breathe. Even if pulled tightly over the nose and mouth, air passes through and allows for
respirations. There was no clinical evidence that Mr. Mears was unable to breathe through the spit
mask, and his oxygen levels were not documented as being abnormal. To date, there are no reports
in the medical literature that identify spit masks as a cause of asphyxiation. The spit mask did not
have any contributing effects to the subject's death.

5. Mr. Mears had an enlarged heart that placed him at significant risk ofgoing into sudden
curdiac arrest and dying.

- 11 -

Case 2:15-cv-08441-JAK-AJW Document 47-2 Filed 04/03/17 Page 13 of 20 Page ID
#:379

Additionally, besides being in a state of ExDS, Mr. Mears had a hemt that was significantly
enlarged, weighing 640 grams. The normal sized heart for a male is typically 300-350g and some
sources note possibly up to 400g depending on body size. On autopsy, the structure of Mr. Mears'
heart was abnormal as he was noted to have biventricular hypettrophy and four chamber dilatation
noted. These are pathological and abnormal enlargements of the heart, not uncommon in people
who use drugs like cocaine, and is the most likely cause in this case. This significant physical
enlargement of the heart in and of itself can place an individual at increased risk for sudden cardiac
arrest and death from an irregular heartbeat.
Given that the increased amount of cardiac tissue mass increases total oxygen demand
compared with a normal sized heatt, the heatt's need for oxygen can outstrip the available oxygen
in the blood supply in times of significant exertion, like an ongoing struggle and cocaine use. This
will result in some of the heart tissue not getting enough blood flow and oxygen, which then causes
cardiac ischemia which then results in the hemt going into sudden cardiac arrest, as occurred with
Mr. Mears.

6. Mr. Mears was suffering signs and symptoms consistent with excited delirium syndrome
due to his cocaine use, which in and of itself can cause sudden cardiuc arrest.
Excited Delirium Syndrome (ExDS) is a syndrome most commonly caused by use of
stimulant drugs like cocaine, methamphetamine or PCP and presents typically with aggressive and
often paranoid behavior, but can also be caused by uncontrolled and untreated psychiatric illnesses,
particularly schizophrenia. In fact, the original description ofExDS symptoms was in psychiatric
patients. And in the days before there were medications to treat these patients, the mottality rate
was reported at 75%. Currently, the majority of cases occurs in subjects using illicit drugs and is a
significant cause of sudden cardiac arrest.
Classically, people suffering from ExDS are delusional often hallucinating, are hyperactive,
may be violent despite threats or overwhelming force, fight inappropriately, be inappropriately

- 12 -

Case 2:15-cv-08441-JAK-AJW Document 47-2 Filed 04/03/17 Page 14 of 20 Page ID
#:380

dressed for the conditions or take off their clothes, may be sweaty, have elevated body
temperatures, and are often breathing fast. They are also often destructive and typically described
as having superhuman strength. The subjects who tend to suffer sudden death are commonly noted
to have elevated body temperatures.
The actual pathophysiology of ExDS is complex and not well understood. Anatomic and
molecular evaluation of ExDS patients who die has focused primarily on postmortem brain
examinations. Results demonstrate a characteristic loss of the dopamine transp01ier in the striatum
of chronic drug abusers who die with clinical presentations consistent with and a diagnosis of
ExDS. This suggests that one potential pathway for the development of ExDS is excessive
dopamine stimulation in the striatum.
Even more supportive of central dopamine stimulation as a pathway is the fact that
hypothalamic dopamine receptors are responsible for thermoregulation. These disturbances of
dopamine neurotransmission may help explain the profound elevated temperatures reported in many
ExDS patients as well as elevated levels of heat shock proteins, which are found in nearly every cell
and act to protect cell proteins from a variety of stressors. The central dopamine hypothesis also
provides a link to psychiatric etiologies and the delirious presentation in patients with ExDS.
ExDS places the individual at increased risk for sudden death syndrome, felt by most experts
to be caused by an irregular or stoppage of the heartbeat, caused by the increased stress and work on
the heart by the excited, over-stimulated, agitated physical state. There are data that this state is
caused by a central brain effect and changes in neurotransmitter receptors. Once the heati goes into
an irregular beat or stops, blood flow through the body ceases and shortly thereafter, the subject will
lose consciousness due to lack of blood flow to the brain and stops breathing. Often, law
enforcement officers will notice that the subject has quieted down, thinking that he has finally
calmed down and given up the fight. Then a short time later is when someone will identify that the
subject is suddenly in cardiac arrest.

- 13 -

Case 2:15-cv-08441-JAK-AJW Document 47-2 Filed 04/03/17 Page 15 of 20 Page ID
#:381

The symptoms and findings for ExDS were described above, and Mr. Mears demonstrated
many of the signs ofExDS. Mr. Mears exhibited paranoid behavior thinking that someone was out
to get him. Delusions are a necessary component in the diagnosis ofExDS. Also, he had cocaine
metabolite reported in his urine toxicology screen, and cocaine is a drug commonly associated with
ExDS. He was described as him having significant strength. He also kept on trying to get up and
resisted despite multiple uses of the TASER ECO, demonstrating tolerance to pain. Additionally,
he was rolling around in broken glass and bleeding, demonstrating this pain tolerance. Overall, this
clinical presentation by Mr. Mears is consistent with ExDS.
Elevated body temperature is often associated with ExDS. The body temperature
documented at 103.5 degrees Fahrenheit. This is also consistent with ExDS. Not all people
suffering from ExDS go into cardiac arrest and die, but when they do, they commonly have an
elevated body temperature. Finally, the initial cardiac rhythm ofpulseless electrical activity (PEA)
is also classic for ExDS.
Clinically, Mr. Mears was suffering the signs and symptoms consistent with a diagnosis of
excited delirium syndrome. He had an elevated temperature. He was delusional, having paranoid
thoughts. He was not compliant with officers' commands and continued to struggle despite the use
of the TASER ECO and officers trying to restrain him, and did not appear impacted by pain, as
evidenced by his continued attempts to try to get up despite the TASER ECO use and rolling in
broken glass. This was his clinical presentation.
To conclude that a person was actually suffering from ExDS and make the diagnosis, there
needs to be inciting etiology, a cause. The two main recognized etiologies are active drug use of a
stimulant drug, like cocaine or methamphetamine, or an untreated or under treated psychiatric
disorder like schizophrenia or bipolar disorder. Mr. Mears had cocaine metabolites in his drug
screen.

Mr. Mears was demonstrating the classic presentation ofExDS from his cocaine use, and

- 14 -

Case 2:15-cv-08441-JAK-AJW Document 47-2 Filed 04/03/17 Page 16 of 20 Page ID
#:382

this cocaine induced ExDS, in combination with cardiac abnormalities and life threatening elevated
potassium levels, is the probable cause of his sudden cardiac arrest.

4. The significant ltyperkalemia (elevated potassium levels) that Mr. Mears !tad contributed
to his cardiac arrest and sudden death.

Mr. Mears was found to have a potassium level of7.4 at the time of his emergency
department evaluation. The cause of this elevation is most likely due to acute kidney dysfunction
from his recent cocaine use. This elevation was not caused by or worsened by the interaction with
the officers.
By way of comparison, a normal potassium level is 3.5-5.0. Patients with chronic kidney
failure on dialysis can get upto levels of6.0 to 7.5 with little in the way of clinical findings, but
other patients with acute elevations in potassium will have EKG changes at these levels and are
already at significant risk to go into sudden cardiac arrest. Mr. Mears, with a potassium of greater
than 7 was at increased risk to go into cardiac arrest at any moment, with or without any
involvement by law enforcement. This severe hyperkalemia, along with his ExDS from his cocaine
use, his ongoing struggling, and his underlying cardiac abnormality in combination is the cause of
Mr. Mears' sudden cardiac arrest and ultimately his death.

Background

My background is that I am a full time faculty member in the department of emergency
medicine at the University of California, San Diego Medical Center. I am residency trained and
board certified in Emergency Medicine. I work full time as a practicing clinician in the Emergency
Department of a busy urban hospital and serve as the clinical operations chief for our two

- 15 -

Case 2:15-cv-08441-JAK-AJW Document 47-2 Filed 04/03/17 Page 17 of 20 Page ID
#:383

emergency departments with a combined annual census of approximately 70,000 visits. I currently
serve as the Medical Director for Risk Management for the UC San Diego Health System. I also
serve as the UCSD Medical Center's Medical Risk Management Committee Chair and Allocation
Committee Co-Chair, as well as previously having served as the Chair of the Patient Care and Peer
Review Committee, each of which are charged with the task of reviewing medical records and
making determinations of standard of care. I am also the former Chief of Staff for the UCSD
Medical Center.
I have worked for over 20 years as a faculty emergency physician at an urban-based
emergency department that is contracted to receive patients who in custody, both as field arrests and
for on-going care while incarcerated. I served as the UCSD Director of Custody Services
overseeing hospital services for the San Diego County Sheriffs Depatiment Medical Services for
16 years. I also have worked in a jail setting for over 18 years, staffing weekly sick call clinics on
site at the San Diego Sheriffs jails throughout San Diego County. I have also served as the on-site
medical director for the San Diego Sheriffs medical clinics for 16 years where I have trained staff
physicians, paiiicipated in quality assurance, resource utilization, policy and protocol development
and peer review. I have also overseen the physician staffing for seven jails in San Diego County
over that time.
My Emergency Medical Services (EMS)/prehospital background and experience includes
having been a flight physician with Lifeflight of San Diego and with Mercy Air, taking care of
acutely injured patients at the scene. My EMS administrative roles include having been the Base
Station Medical Director for UCSD, the Medical Director for the Palomar and Southwestern
Paramedic College Training Programs, and the former Medical Director for the County of San
Diego Emergency Medical Services (EMS) one of the largest EMS systems in the nation. In this
role I was responsible for protocols and quality assurance of over 1000 paramedics and 4000
EMT's. I started the UCSD EMS/Disaster Medicine Fellowship Training Program and was the first

- 16 -

Case 2:15-cv-08441-JAK-AJW Document 47-2 Filed 04/03/17 Page 18 of 20 Page ID
#:384

Fellowship Director and currently serve as the Assistant Director of the EMS/Disaster Medicine
Division in the UCSD Depa1tment of Emergency Medicine and as the Medical Director for
Carlsbad Fire Department and AirLinkUSA Air Ambulance Service. Other previous roles include
have been the Medical Director for the San Diego County Metropolitan Medical Strike Team
(MMST) and serving as medical back up for many SWAT operations. I am also the Principal
Investigator for San Diego's Resuscitative Outcomes Consortium (ROC) site, a National Institute of
Health (NIH) funded study to evaluate treatment options for out of-hospital cardiac arrest and
severe traumatic injury including gunshot injuries.
I am knowledgeable of peer-reviewed medical and scientific research on TASER electronic
control devices (ECDs) conducted by others. In fact, I was the lead author on work requested by
the American Academy of Emergency Medicine (AAEM) to review the totality of the peer
reviewed published medical literature on humans and come to conclusions regarding the necessary
emergency department evaluation of patients being seen after receiving a TASER ECO activation.
have received federal grant funding and performed extensive clinical research on human subjects
who have received TASER ECO applications (atticles included in my curriculum vitae) which
includes having been involved with over 200 TASER ECO activations and have personally received
multiple applications of the device. 1 have written several book chapters on this topic and have
lectured internationally about the physiologic effects of TASER ECDs.
I am knowledgeable of peer-reviewed medical and scientific research on the physiological
effects of positional restraint and positional asphyxia conducted by others. I have also performed
extensive clinical research on human subjects who have been restrained in various positions and
with various amounts of weight being placed (aiticles included in my curriculum vitae) which
includes having directly been involved with hundreds of subjects being restrained and studied,
hundreds of patients restrained during my work in the emergency department and have personally
been restrained with weights placed on me as well. I have been invited to lecture nationally and

- 17 -

Case 2:15-cv-08441-JAK-AJW Document 47-2 Filed 04/03/17 Page 19 of 20 Page ID
#:385

internationally on this subject. Given my own interests in this area, I regularly perform a complete
review of the literature regarding restraints and in custody death.
I am knowledgeable of peer-reviewed medical and scientific research on OC spray. I have
written several peer reviewed papers and textbook chapters on this topic and have been invited to
lecture on this topic. 1 have been exposed to OC spray personally and given my own interests in
this area, I regularly perform a complete review of the literature regarding OC spray.
I am knowledgeable of peer-reviewed medical and scientific research for cardiac arrest and
CPR practices. I was the Principle Investigator for San Diego's Resuscitative Outcomes
Consortium (ROC) site, a National Institute of Health (NIH) funded study for ten years that
involved over 200,000 cardiac arrest patients to evaluate treatment options for out of-hospital
cardiac arrest and severe traumatic injury. I have published many peer-reviewed papers on the topic
of cardiac arrest and cardiac resuscitation. I also serve as the Medical Director of the American
Heart Association Training Center at the University of California, San Diego Center for
Resuscitation Science since 2007, teaching Advanced Cardiac Life Support (ACLS) both locally
and being asked to give lectures on cardiac arrest internationally. I have been an ACLS instructor
for over 20 years. I also work at a busy urban comprehensive emergency depaiiment where I care
for patients in cardiac arrest on a regular basis.
I was the lead author on work requested by the American College of Emergency Physicians
(ACEP) to review the totality of the body of literature on the topic of Excited Delirium Syndrome
(ExDS) and wrote up the findings of the expert consensus panel's white paper. I have published
several papers on the topic, have been grant funded by the National Institute of Justice to study
patients with ExDS and invited to write text book chapters on the topic ofExDS. I have also been
invited to lecture nationally and internationally on the topics of Excited Delirium Syndrome.
As per Rule 26 formatting, Appendix A is a copy of my current Curriculum Vitae, which
includes a list of all publications authored by me. Appendix B is a list of all cases in which I have

- 18 -

Case 2:15-cv-08441-JAK-AJW Document 47-2 Filed 04/03/17 Page 20 of 20 Page ID
#:386

testified as an expert in trial or deposition within the preceding four years. Appendix C is my fee
schedule. The knowledge base that I utilize has been developed over time from my years of
clinical practice and experience, reading and training as well as research. Under penalty of perjury,
I hereby swear that the opinions stated above are true and correct within a reasonable degree of
medical probability.

Respectfully submitted,

Gary M. Vilke, M.D., FACEP, FAAEM
Professor of Clinical Emergency Medicine
Emergency Medicine Clinical Service Chief and Co-Medical Director
Medical Director, Risk Management, UC San Diego Health
Director, Clinical Research for Emergency Medicine

- 19 -